Secure Web Gateway Model F Appliances Data Sheet
Hardware Specifications | WBG-5500-F | WBG-5000-F |
---|---|---|
Form Factor | CSE-LB16AC10-R860AW3-1U | CSE-LB16AC10-R860AW3-1U |
Processor | 2 x CPU, SPR, XEON GOLD 5418Y, 2.0 GHZ, 24CC, 45MB CACHE | 1 x CPU, SPR, XEON SILVER 4410Y, 2.0 GHZ, 12CC, 30MB CACHE |
Memory | 12 x 16GB, DDR5, 4800MHZ, RDIMM, ECC, 1RX8 | 4 x 16GB, DDR5, 4800MHZ, RDIMM, ECC, 1RX8 |
Network Interface | 4 x 10Gbps PCIe ports RJ45 | 4 x 10Gbps PCIe ports RJ45 |
Optional Optical Network Card |
MAP-10G4SR-FBRF, 10 GbE fiber - 4 ports MAP-10G4LR-FBRF, 10 GbE fiber - 4 ports |
MAP-10G4SR-FBRF, 10 GbE fiber - 4 ports MAP-10G4LR-FBRF, 10 GbE fiber - 4 ports |
Maximum Throughput2 | 6250 Mbps | 5430 Mbps |
USB Interfaces |
Front: 2 x USB 2.0 Ports Back: 2 X USB 3.1 Ports |
Front: 2 x USB 2.0 Ports Back: 2 X USB 3.1 Ports |
Serial Interface | 1 COM Port | 1 COM Port |
RAID | RAID 1 | RAID 1 |
SSD | 2 x SSD, 2.5", 960GB, SATA | 2 x SSD, 2.5", 960GB, SATA |
Voltage | Auto Switch 110/220 V | Auto Switch 110/220 V |
Input Voltage Range |
100-127Vac / 9A-7.5A / 50-60Hz 200-240Vac / 6A-4.5A / 50-60Hz |
100-127Vac / 9A-7.5A / 50-60Hz 200-240Vac / 6A-4.5A / 50-60Hz |
Power Rating | 1200W | 1200W |
Dimensions |
Height: 1.7 in or 43 mm Width: 17.2 in or 437 mm Depth: 23.5 in or 597 mm |
Height: 1.7 in or 43 mm Width: 17.2 in or 437 mm Depth: 23.5 in or 597 mm |
Maximum Weight | 40 lbs or 18.1 kg | 40 lbs or 18.1 kg |
Remote Access | ASPEED AST2600 BMC | ASPEED AST2600 BMC |
Power Supply Unit | 1200 WATTS, TITANIUM PSU redundant | 1200 WATTS, TITANIUM PSU redundant |
Motherboard | X13DDW-A | X13DDW-A |
Environmental and Regulatory Specifications | ||
---|---|---|
Operating Temperature | 10°C ~ 35°C (50°F ~ 95°F) | 10°C ~ 35°C (50°F ~ 95°F) |
Non-Operating Temperature | -40°C to 60°C (-40°F to 140°F) | -40°C to 60°C (-40°F to 140°F) |
Acoustic Noise | ISO 7779 [ Byslander test, with fan speed control enable and full speed] | ISO 7779 [ Byslander test, with fan speed control enable and full speed] |
Shock, Operating | 2.5 ms duration, 20G, half-sine, one shock on each side | 2.5 ms duration, 20G, half-sine, one shock on each side |
Shock, non-operating |
10 ms duration, 10-20G, square wave, one shock on each side |
10 ms duration, 10-20G, square wave, one shock on each side |
Vibration (Sinusoidal) operating |
0.25 G at 5 to 200 Hz. Approx 15 min/axis |
0.25 G at 5 to 200 Hz. Approx 15 min/axis |
Vibration (Sinusoidal) Non-operating |
0.50 G at 5 to 200 Hz. Approx 15 min/axis |
0.50 G at 5 to 200 Hz. Approx 15 min/axis |
Vibration (Random) operating |
0.40 rms at 5 to 200Hz. Approx 60min/axis |
0.40 rms at 5 to 200Hz. Approx 60min/axis |
Vibration (Random) Non-operating |
0.98 rms at 5 to 200Hz. Approx 60min/axis |
0.98 rms at 5 to 200Hz. Approx 60min/axis |
Operating Relative Humidity |
8% to 90% (non-condensing) |
8% to 90% (non-condensing) |
Non-operating Relative Humidity |
5% to 95% (non-condensing) |
5% to 95% (non-condensing) |
Safety | ||
---|---|---|
EN 60950-1:2006/A11:2009/A1:2010/A12:2011 |
Yes |
Yes |
EN 62368-1:2014 |
Yes |
Yes |
IEC 62368-1:2014 |
Yes |
Yes |
UL 62368-1: 2014 |
Yes |
Yes |
EN 62368-1:2018 |
Yes |
Yes |
IEC 62368-1:2018 |
Yes |
Yes |
China GB4943.1-2011 |
Yes |
Yes |
EMC | ||
---|---|---|
Title 47 of the CFR, Part 15, Class A |
Yes |
Yes |
ICES-003 Issue 4, February 7, 2004 Class A |
Yes |
Yes |
EN55032:2015 |
Yes |
Yes |
EN 55035:2017 |
Yes |
Yes |
China GB17625.1:2012 |
Yes |
Yes |
KS C 9832: 2019 and KS C 9835:2019 |
Yes |
Yes |
CISPR 32:2015 |
Yes |
Yes |
VCCI-CISPR 32:2016 |
Yes |
Yes |
Emissions (Australia/NZ) |
Yes |
Yes |
Country Of Approval | WBG-5500-F | WBG-5000-F |
---|---|---|
USA |
Yes |
Yes |
Canada |
Yes |
Yes |
European Union (CE Mark) |
|
|
China CCC |
In-progress |
In-progress |
EAC (Euro-Asia Conformity) Russia, Kazakhstan, and Belarus |
Yes |
Yes |
South Africa LoA |
Yes |
Yes |
Korea MISP |
Yes |
Yes |
Australia/New Zealand |
Yes |
Yes |
Israel |
Yes |
Yes |
Japan |
Yes |
Yes |
Throughput values are listed as maximums for forward proxy deployment. Security features are enabled within the proxy impact throughput and should be evaluated upon sizing.