Secure Web Gateway Model F Appliances Data Sheet
Hardware Specifications | WBG-5500-F | WBG-5000-F |
---|---|---|
Form Factor | CSE-LB16AC10-R860AW3-1U | CSE-LB16AC10-R860AW3-1U |
Processor | 2 x CPU, SPR, XEON GOLD 5418Y, 2.0 GHZ, 24CC, 45MB CACHE | 1 x CPU, SPR, XEON SILVER 4410Y, 2.0 GHZ, 12CC, 30MB CACHE |
Memory | 12 x 16GB, DDR5, 4800MHZ, RDIMM, ECC, 1RX8 | 4 x 16GB, DDR5, 4800MHZ, RDIMM, ECC, 1RX8 |
Network Interface | 4 x 10Gbps PCIe ports RJ45 | 4 x 10Gbps PCIe ports RJ45 |
Optional Optical Network Card |
MAP-10G4SR-FBRF, 10 GbE fiber - 4 ports MAP-10G4LR-FBRF, 10 GbE fiber - 4 ports |
MAP-10G4SR-FBRF, 10 GbE fiber - 4 ports MAP-10G4LR-FBRF, 10 GbE fiber - 4 ports |
Maximum Throughput1 | 6250 Mbps | 5430 Mbps |
USB Interfaces |
Front: 2 x USB 2.0 Ports Back: 2 X USB 3.1 Ports |
Front: 2 x USB 2.0 Ports Back: 2 X USB 3.1 Ports |
Serial Interface | 1 COM Port | 1 COM Port |
RAID | RAID 1 | RAID 1 |
SSD | 2 x SSD, 2.5", 960GB, SATA | 2 x SSD, 2.5", 960GB, SATA |
Voltage | Auto Switch 110/220 V | Auto Switch 110/220 V |
Input Voltage Range |
100-127Vac / 9A-7.5A / 50-60Hz 200-240Vac / 6A-4.5A / 50-60Hz |
100-127Vac / 9A-7.5A / 50-60Hz 200-240Vac / 6A-4.5A / 50-60Hz |
Power Rating | 1200 W | 1200 W |
Power Consumption2 | 733 W | 448.2 W |
Dimensions |
Height: 1.7 in or 43 mm Width: 17.2 in or 437 mm Depth: 23.5 in or 597 mm |
Height: 1.7 in or 43 mm Width: 17.2 in or 437 mm Depth: 23.5 in or 597 mm |
Maximum Weight | 40 lbs or 18.1 kg | 40 lbs or 18.1 kg |
Remote Access | ASPEED AST2600 BMC | ASPEED AST2600 BMC |
Power Supply Unit | 1200 WATTS, TITANIUM PSU redundant | 1200 WATTS, TITANIUM PSU redundant |
Motherboard | X13DDW-A | X13DDW-A |
Environmental and Regulatory Specifications | ||
---|---|---|
Operating Temperature | 10°C ~ 35°C (50°F ~ 95°F) | 10°C ~ 35°C (50°F ~ 95°F) |
Non-Operating Temperature | -40°C to 60°C (-40°F to 140°F) | -40°C to 60°C (-40°F to 140°F) |
Acoustic Noise | ISO 7779 [ Byslander test, with fan speed control enable and full speed] | ISO 7779 [ Byslander test, with fan speed control enable and full speed] |
Shock, Operating | 2.5 ms duration, 20G, half-sine, one shock on each side | 2.5 ms duration, 20G, half-sine, one shock on each side |
Shock, non-operating |
10 ms duration, 10-20G, square wave, one shock on each side |
10 ms duration, 10-20G, square wave, one shock on each side |
Vibration (Sinusoidal) operating |
0.25 G at 5 to 200 Hz. Approx 15 min/axis |
0.25 G at 5 to 200 Hz. Approx 15 min/axis |
Vibration (Sinusoidal) Non-operating |
0.50 G at 5 to 200 Hz. Approx 15 min/axis |
0.50 G at 5 to 200 Hz. Approx 15 min/axis |
Vibration (Random) operating |
0.40 rms at 5 to 200Hz. Approx 60min/axis |
0.40 rms at 5 to 200Hz. Approx 60min/axis |
Vibration (Random) Non-operating |
0.98 rms at 5 to 200Hz. Approx 60min/axis |
0.98 rms at 5 to 200Hz. Approx 60min/axis |
Operating Relative Humidity |
8% to 90% (non-condensing) |
8% to 90% (non-condensing) |
Non-operating Relative Humidity |
5% to 95% (non-condensing) |
5% to 95% (non-condensing) |
Safety | ||
---|---|---|
EN 60950-1:2006/A11:2009/A1:2010/A12:2011 |
Yes |
Yes |
EN 62368-1:2014 |
Yes |
Yes |
IEC 62368-1:2014 |
Yes |
Yes |
UL 62368-1: 2014 |
Yes |
Yes |
EN 62368-1:2018 |
Yes |
Yes |
IEC 62368-1:2018 |
Yes |
Yes |
China GB4943.1-2011 |
Yes |
Yes |
EMC | ||
---|---|---|
Title 47 of the CFR, Part 15, Class A |
Yes |
Yes |
ICES-003 Issue 4, February 7, 2004 Class A |
Yes |
Yes |
EN55032:2015 |
Yes |
Yes |
EN 55035:2017 |
Yes |
Yes |
China GB17625.1:2012 |
Yes |
Yes |
KS C 9832: 2019 and KS C 9835:2019 |
Yes |
Yes |
CISPR 32:2015 |
Yes |
Yes |
VCCI-CISPR 32:2016 |
Yes |
Yes |
Emissions (Australia/NZ) |
Yes |
Yes |
Country Of Approval | WBG-5500-F | WBG-5000-F |
---|---|---|
USA |
Yes |
Yes |
Canada |
Yes |
Yes |
European Union (CE Mark) |
|
|
China CCC |
In-progress |
In-progress |
EAC (Euro-Asia Conformity) Russia, Kazakhstan, and Belarus |
Yes |
Yes |
South Africa LoA |
Yes |
Yes |
Korea MISP |
Yes |
Yes |
Australia/New Zealand |
Yes |
Yes |
Israel |
Yes |
Yes |
Japan |
Yes |
Yes |
NOTES:
1Throughput values are listed as maximums for forward proxy deployment. Security features are enabled within
the proxy impact throughput and should be evaluated upon sizing.
2Power consumption values are listed as maximums for a standard configuration where you run an
appliance out-of-the-box with no additional network interface cards, nor a Hardware Security Module (HSM),
nor any other additional components installed.